Certified by WERCS Inc

Junair · Downdraft

Junair 5 Series

Filter kit, alternatives, and current pricing for the 5 Series.

Junair model • 5 Series

Junair 5 Series Filter Program

Junair's flagship downdraft: plenum-fed full-ceiling input media and EVAC EX floor extraction, mapped to your booth on the first fitment check.

Flagship in this ladder is a specific claim, not marketing shorthand: the 5 Series carries the largest burner band, the strongest fan options, and a 45 to 100A draw on its 415V three-phase supply per the UK specification sheet. The standard-equipment list is what separates it at the filter level. Where lower rungs treat floor extraction and plenum distribution as configuration choices, the 5 Series ships with EVAC EX or LEVAC EX floor extraction and a full-width plenum by default, so every 5 Series filter program starts from the same airflow architecture.

Quick answer

EVAC EX floor extraction and a full-width ceiling plenum come standard on the Junair 5 Series, the flagship rung of the brand's numbered booth ladder. The specification sheet lists burner options from 212 to 380kW, roughly 1,010,000 BTU per hour at the midpoint, and fan options from 7.5 to 18.5kW, the heaviest package Junair publishes for the range. For filters that means a full-ceiling input stage fed by the plenum and exhaust media at engineered floor extraction points, both confirmed by fitment check because no SKU cross-references are on file yet for this model.

By BoothFilterPro Editorial · Filter Fitment Desk · Updated Jul 15, 2026

How 5 Series shops choose filters

Plenum-fed ceiling. The full-width plenum distributes supply air across the entire ceiling input stage before it ever reaches the media. For the filter program that means the ceiling media loads evenly edge to edge, which extends usable life compared to point-fed designs, and it means a single degraded panel disturbs a column that is otherwise very straight. Change the input stage as a complete set.

Floor extraction. EVAC EX and LEVAC EX are the sheet's standard floor extraction packages. Exhaust arrestor media sits at the floor extraction points and is sized to that layout. Our record does not document the opening dimensions, so the first fitment check maps them, and every reorder rides on that map.

Throughput reality. Shops buy the top rung for volume, and media consumption follows paint volume, not booth prestige. A 5 Series doing heavy collision throughput can outconsume a smaller booth several times over. The strong fan band masks loading longer than a 1 Series fan would, which makes the exhaust manometer more important here, not less: by the time airflow visibly sags on an 18.5kW fan option, the media is well past due.

Regulatory landscape

The 5 Series' architecture lines up with what EPA 6H expects of an area-source refinisher: enclosed, ventilated, filtered spraying maintained to manufacturer specification, with the specification sheet itself serving as the reference document. OSHA 1910.94(c) holds ventilation performance at the working zone regardless of how large the fan package is, and NFPA 33 requires exhaust arrestors changed before combustible overspray accumulates at the extraction points. High-throughput shops should note that compliance exposure scales with volume: more spraying means more frequent documented changes, which is where subscription delivery records earn their keep.

Who runs the 5 Series

Three buyer profiles account for most 5 Series installs. High-volume collision centers, often dealer-affiliated, that specified the flagship for throughput and uptime. Commercial and fleet refinishers pushing heavier coating volumes through the booth than a typical bodyshop, who will replace floor media on the shortest cycles on this page. And established shops consolidating from two older booths into one flagship bay, for whom the filter program is simpler than what they left behind: one input set, one floor extraction map, one reorder cadence.

5 Series filter FAQs

What are EVAC EX and LEVAC EX on the 5 Series?

They are the floor extraction packages the Junair specification sheet lists as standard on this model, paired with the full-width plenum. For filter buying, they define where exhaust media lives: at floor extraction points sized during your fitment check.

Does the 5 Series use different filter media than the 3 Series?

The media types are the same family: EU5-class input media at the ceiling and arrestor media at the floor. What differs is the exhaust stage layout, since EVAC EX extraction is standard here, and the quantities your layout consumes.

What power supply does the specification sheet list?

415V three-phase at 50Hz, drawing 45 to 100A depending on build. That is a UK-market figure; North American installs are configured by the importer or installer, which changes nothing about the filter program itself.

Why is there no SKU list on this page?

The record is built from Junair's specification sheet and carries needs-verification status. No distributor SKU cross-references are on file yet, so slot sizes are confirmed per booth, and confirmed dimensions become your standing fitment record.

Does the big burner package change which filters I need?

No. Burner rating affects heat, not media selection. Keep the input stage healthy to protect the air handling behind it, and let paint volume and the manometer set your change cadence.

Sources

Primary references cited on this page.

Related on BoothFilterPro