Certified by WERCS Inc

Junair · Downdraft

Junair 3 Series

Filter kit, alternatives, and current pricing for the 3 Series.

Junair model • 3 Series

Junair 3 Series Filter Program

Full downdraft middle rung: full-ceiling EU5 input media and floor-level extraction, with slot sizes confirmed by fitment check before bulk orders.

Ladder positioning explains this booth better than any single spec. Below it, the 1 Series covers entry semi-downdraft work; above it, the 5 Series adds engineered floor extraction and the heaviest fan and burner package as the flagship. The 3 Series is the volume rung: full downdraft airflow and a full-ceiling input stage on a 415V three-phase supply drawing 20 to 63A per the UK specification sheet, in the same listed 7,000mm by 4,000mm by 2,500mm working chamber as its siblings. For filters, full downdraft is the line that matters, because it changes both what you buy and how much of it.

Quick answer

A burner band of 100 to 300kW and fan options from 3.0 to 11kW give the Junair 3 Series the widest tuning range in the brand's numbered ladder. It is also the rung where Junair goes full downdraft: a full-ceiling EU5 input filter feeds air straight down over the vehicle to floor-level extraction. The manufacturer's specification sheet documents the mechanical package; filter slot dimensions are not cross-referenced to SKUs yet, so media for the ceiling and floor stages is confirmed by fitment check before bulk ordering.

By BoothFilterPro Editorial · Filter Fitment Desk · Updated Jul 15, 2026

How 3 Series shops choose filters

Full-ceiling input. On the 3 Series the entire ceiling is the input stage, EU5-class media distributed across the footprint. That is what produces the even, straight-down air column, and it also means input media consumption per change is a step up from the 1 Series' partial-ceiling panel. Budget for it; starving the ceiling change to save money shows up directly on the horizontal panels of the next paint job.

Floor extraction. Exhaust media lives at floor level. The openings are not documented in our record, so arrestor media, fiberglass or pocketed paper, is cut to your measured extraction layout. One measurement session covers every reorder.

Spec spread. The 100 to 300kW burner band and 3.0 to 11kW fan options mean two 3 Series booths can carry meaningfully different mechanical packages. Higher-fan builds tolerate more media loading before velocity drops, but the manometer, not the spec plate, should still call the change.

Regulatory landscape

Full-downdraft booths make 6H compliance easier to demonstrate, not automatic. The area-source rule expects spraying inside a filtered, ventilated booth maintained to specification, and the full-ceiling input plus floor extraction on the 3 Series is exactly the configuration inspectors are used to seeing; the gap that gets shops written up is missing change documentation, which delivery records close. OSHA 1910.94(c) requires the ventilation to actually perform at the working zone, and NFPA 33 requires arrestors changed before overspray accumulates as combustible loading. A booth this capable fails those standards only through neglected media.

Who runs the 3 Series

The 3 Series shows up as the primary production booth in established independent collision shops: enough airflow and heat for steady throughput without flagship cost. It also appears in dealer-group bodyshops as the standard bay spec, often several identical units in a row, where consolidated filter ordering across bays is the real workflow win. A smaller third group runs the 3 Series for industrial coating on parts and fabrications, where heavier spray volumes push floor media harder than collision work does.

3 Series filter FAQs

Is the Junair 3 Series a true downdraft?

Yes. The specification sheet lists a full-ceiling EU5 input filter with floor-level extraction, which is the full downdraft layout: air in across the whole ceiling, straight down, and out at the floor.

How much input media does the full ceiling take per change?

The full ceiling area is the input stage, so consumption is a step up from the semi-downdraft 1 Series. Exact quantities depend on your housing layout, which is what the fitment check documents before your first bulk order.

What is the filter difference between the 3 Series and the 5 Series?

The 5 Series adds EVAC EX floor extraction and a full-width plenum as standard, with a heavier fan and burner package. The buying difference is in the exhaust stage layout; both rungs run full-ceiling input media.

Why does my spec plate show a different burner rating than another 3 Series?

Junair listed the 3 Series with burner options from 100 to 300kW and fans from 3.0 to 11kW, so individual builds vary widely. Filter media type does not change with the mechanical package, but loading tolerance does.

When is the floor extraction media due?

When the manometer across the exhaust stage hits the media's rated pressure-drop limit, or earlier if overspray buildup is visible. Fixed calendars overshoot or undershoot depending on paint volume, so read the gauge.

Sources

Primary references cited on this page.

Related on BoothFilterPro