
Global Finishing Solutions · Crossdraft
Global Finishing Solutions Performer
Filter kit, alternatives, and current pricing for the Performer.
Required filters
Recommended kit for this booth
3 matched filters across 4 slots.
Complete kit total · $663.39
Intake side (clean air going in) (2 slots)

Ceiling intake
Ceiling diffusion polyester · 51"X121"
Special order · 1–2 weeksFiltrair FF560GX Diffusion Filter 51"X121"
02560511216Quote on request

Wall intake
Tackified intake panel · 20x20
In stock · ships in 24hTackified Intake Filter Panel 20" x 20"
BFP-TKI-20X20· 30–60 day cycle$273.77
Exhaust side (overspray coming out) (2 slots)

Exhaust Wall
Paper mesh / kraft baffle · 20x20
Special order · 1–2 weeksPaper-Mesh Kraft Arrestor 20" x 20"
BFP-PMK-20X20· 14–28 day cycle$81.03

Wall exhaust (grid)
Pocketed paper arrestor · 30"X50'
Special order · 1–2 weeksPaint Pockets Roll
PP-030-050-001$308.59
Not finding the right match?
We carry many filters beyond what's shown here. Tell us about your booth and we'll send you a price and ship ETA within one business day.
Don't see your filter? Request a quote →Global Finishing Solutions model • Performer
GFS Performer Filter Cross-Reference
Four cross-referenced SKUs for the Performer crossdraft family: exhaust arrestor rolls, AMU prefilter bag, and plenum diffusion media, confirmed to your configuration.
The Performer earned its ubiquity the ordinary way: long production runs and broad distribution as the value entry in the GFS lineup, sitting below the flagship Ultra downdraft family. That ubiquity cuts both ways for filter buying. Aftermarket suppliers list media against the Performer name freely, but the line spans configurations, and our slot map for it carries needs-verification status. The compatible SKUs above are cross-referenced from distributor and manufacturer catalogs; which of them your booth actually takes depends on how your intake and exhaust are built, and one photo or measurement settles that.
Quick answer
Few booth models show up on more aftermarket filter listings than the Performer, Global Finishing Solutions' long-running crossdraft line. Air moves horizontally through this booth: in through filtered intake at the front, across the vehicle, and out through an exhaust wall grid. Distributor cross-references list four SKUs against the Performer family: a 22 gram fiberglass arrestor roll (14AG30300, 30" x 300'), a Paint Pockets pocketed-paper roll (PP-030-050-001, 30" x 50'), a six-pocket AMU prefilter bag (04F244862), and a Filtrair FF560GX diffusion panel (02560511216, 51" x 121") for plenum-fed configurations. Confirm your configuration before ordering in bulk.
How Performer shops choose filters
Exhaust side. The exhaust wall grid is the workhorse slot, and the cross-reference gives you two roll options for it. The 22 gram fiberglass arrestor roll (30" x 300') is the economy default, cut to the grid on-site. The Paint Pockets roll (30" x 50') costs more per foot but holds substantially more overspray per change, which pays off in high-volume spraying. Pick one and stay with it so your pressure-drop readings stay comparable change to change.
Intake side. A classic crossdraft Performer draws air through intake media at the front of the booth, usually in the doors or the front face. The cross-reference also lists a Filtrair FF560GX diffusion panel at 51" x 121", which points at plenum-fed configurations within the family. Before ordering intake media, confirm whether your booth breathes through door filters or a plenum; the two take different products.
AMU prefilter. If your installation includes an air make-up unit, the listed six-pocket bag with header (23 1/4" x 47" x 8") protects its coil and burner. Unheated Performers drawing shop air skip this slot entirely, which is a configuration fact worth stating on your first order.
Regulatory landscape
Crossdraft geometry concentrates the compliance story on the exhaust wall, because that grid is the single capture stage between overspray and the stack. EPA 6H expects filter technology achieving at least 98 percent capture efficiency, and on a Performer that is entirely a question of arrestor condition and coverage: gaps or blown-through media at the grid are the failure mode. OSHA 1910.94(c) adds a worker-exposure angle specific to horizontal airflow, since a loaded exhaust wall pushes overspray back into the painter's breathing zone before anything shows on a gauge. NFPA 33 treats the loaded grid as combustible loading, and it also expects bulk roll media stored away from the spray area.
Who runs the Performer
The Performer's installed base tracks its value positioning. Independent shops bought it as a first real booth, and many are still running it decades on. Fleet, truck, and equipment refinishers favor crossdraft economics for work where a downdraft's finish advantages matter less than uptime and cost per change. And larger collision shops keep a Performer as the prep and primer bay beside a downdraft finish booth, where it quietly consumes more exhaust media than the headline booth does.
Performer filter FAQs
Should I run fiberglass or Paint Pockets in the exhaust grid?
Fiberglass (the 22 gram, 30" x 300' roll) is the economical default. Paint Pockets (30" x 50') holds more overspray per change, so high-volume shops change less often. Either works; committing to one keeps your loading data consistent.
My Performer pulls air through a ceiling plenum. Is that normal?
The Performer family spans configurations, and the cross-reference includes a 51" x 121" Filtrair diffusion panel that fits plenum-fed setups. Send a photo of your intake arrangement and we match media to what you actually have.
What does needs-verification mean for this booth?
The four listed SKUs are cross-referenced from distributor and manufacturer catalogs, but the per-slot map for the Performer line is not field-confirmed for every configuration. Your first order doubles as the verification pass for your specific booth.
Do all Performers take the six-pocket AMU bag?
No. Only installations with an air make-up unit use it. Unheated booths drawing filtered shop air have no AMU slot, so confirm your heat setup before adding the bag to a standing order.
How do I know when the exhaust roll media is spent?
Watch static pressure across the grid and watch behavior: overspray drifting back toward the painter is the crossdraft's early warning. Change at the media's rated pressure-drop limit rather than on a fixed calendar.
Sources
Primary references cited on this page.
- EPA 40 CFR Part 63 Subpart HHHHHH (NESHAP 6H)https://www.epa.gov/stationary-sources-air-pollution/national-emissions-standards-paint-stripping-and-miscellaneous
- OSHA 29 CFR 1910.94(c), Ventilation: spray finishing operationshttps://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.94
- NFPA 33, Standard for Spray Application Using Flammable or Combustible Materialshttps://www.nfpa.org/codes-and-standards/nfpa-33-standard-development/33
Related on BoothFilterPro
- All Global Finishing Solutions models
Brand hub
- REVO Speed
Sibling Global Finishing Solutions model
- Truck/Bus Booth
Sibling Global Finishing Solutions model
- Ultra XR
Sibling Global Finishing Solutions model
- Ultra XS
Sibling Global Finishing Solutions model
- Ultra XL
Sibling Global Finishing Solutions model